Teachers.Net
JoinLog in
Teachers.Net

Designing a Flotation Strategy for the Purification of Recyc

By Frank Virzi

  • Science
  • Senior
Activity Time
2-3 class periods of about 50 minutes each
Materials
Plastics, Isopropyl alcohol, sugar, salt, triple beam balances, graduated cylinders
Concepts / Topics
Density, plastics, recycling, measurement

Teams measure plastic densities, test liquid solutions to separate mixed plastics by flotation, then demonstrate and document their purification strategy.

In this lab, your team will be trying to figure out a way to purify recycled plastic materials. Your purification strategy will be based on the fact that different plastic materials have different densities, and you will be using various liquid solutions to separate batches of mixed plastics by flotation.

The Problem

The Happy Plastics Recycling Company will be hiring a firm to solve a problem for them. Happy Plastics now receives about 100 tons of mixed, impure recycled plastics waste every week, and this material needs to be sorted out and purified in order to be used for manufacturing. That's where you come in.

Flotation

Different kinds of plastics have different densities. You will be using this physical property to purify batches of impure plastic pieces by flotation of the mixed plastics in different solvents, so that only one kind of plastic will float (or remain submerged).

Selection Criteria

Happy Plastics Recycling Company will award this contract based on three criteria:

  1. Minimum cost. You will have at your disposal sugar, table salt, water, and isopropyl alcohol. Try to accomplish your purification using as little of these materials as possible. Keep your costs down!

  2. Speed. Here at Happy Plastics, we're looking for the purification process that will enable us to handle the greatest amount of raw material in the shortest amount of time.

  3. Purity of final product.

Procedure

  1. Collect five plastic samples. With your lab partner(s), collect five different kinds of plastic. Chop, break, cut, tear, or crumble the plastic into small pieces approximately the size of Rice Krispies. For each kind of plastic, cut up enough plastic to fill about half of a Dixie Bathroom Cup (about 44 mL of plastic pieces). Label the cups with your names and the kind of plastic in the cup. You should have five Dixie Cups, each containing one kind of chopped-up plastic material. Stack the Dixie Cups one inside the other, and put your stack of plastic pieces in a safe place. Save enough of each plastic sample for yourself to use in your density measurement experiments and in your flotation testing.

  2. Measure the density of each plastic material.
  3. Prepare your solutions and do some flotation experiments. Make up solutions of salt water, sugar water, or isopropyl alcohol and water that will enable you to separate and purify mixtures of your plastic pieces. Try adding one piece each of two different kinds of plastic to a small test tube, and then separate them by adding a solution with a density that will make only one of the pieces float. After you have successfully separated mixtures of two plastics, try your luck at sorting out combinations of three, four, and all five.

    Keep in mind that the plastic pieces MUST be separated on the basis of flotation ONLY; you will not be allowed to hand-sort any plastic pieces during your demonstration.

In order to keep solvent costs to a minimum, you will be given 10 mL of isopropyl alcohol and a small test tube with which to do all of your flotation testing experiments. You may prepare any sugar-water or salt-water solutions that you may need for your demonstration ahead of time.

Separation Demonstration

Half of your grade for this lab will be determined by demonstrating your separation system. Your teacher will randomly pick three out of the five Dixie Cups containing your plastic pieces. About 5–10 pieces of each plastic will be mixed together, and you will purify the mixed plastics while timed.

For your demonstration, you will use a larger test tube that can hold approximately 60 mL of liquid. This will enable the Happy Plastics Quality Control Inspector to judge the purity of the final product.

Time will officially begin when you are handed the test tube containing the pieces of three different kinds of plastic, along with a rubber stopper. Time will officially end when you have scooped out and placed all of your plastic pieces into three watch glasses, which will be provided. Any plastic pieces that you are not able to deliver successfully from the test tube to the watch glass will be taken into account in figuring your “purity” grade.

Remember, your team is working toward three goals:

  1. Use minimum amounts of materials (water, salt, sugar, and ethanol).
  2. Speed.
  3. Purity of your final product.

Plastics Purification Demo Summary

NAME(S) _________________________________________
_________________________________________________
_________________________________________________

Time required to purify __________________ minutes
Approximate purity of final product ____________ %

Materials Used

To be completed by students immediately after the demonstration.

Water ____________________ L
Salt _____________________ g
Sugar ____________________ g
Ethanol __________________ L

Grading Scorecard

Written Lab Report (50 points): __________

Separation Demo (50 points): __________

Time (10 points): __________

  • ____ Under 3:00 minutes (10 points)
  • ____ 3:01–5:00 minutes (6 points)
  • ____ 5:01–9:00 minutes (4 points)
  • ____ Over 9 minutes (0 points)

Purity (10 points): __________

  • ____ 100% (10 points)
  • ____ 90–99% (8 points)
  • ____ 70–89% (5 points)
  • ____ 0–69% (0 points)

Scientific Approach (30 points): __________

  • ____ Measured volumes of liquids carefully
  • ____ Record-keeping during demonstration will enable reliable cost estimate
  • ____ Consulted density data and flotation experiment data to plan purification strategy
  • ____ Scale-up of liquid volumes permitted easy scoop-outs
  • ____ Logical sequence of steps in purification method
  • ____ Volumes of liquids were not measured
  • ____ Cost estimate of procedure not reliable, due to poor or no record-keeping during purification
  • ____ One or more steps of purification method follow no logical sequence
  • ____ No scale-up of liquid volumes, leading to difficulty with scoop-outs

Teachers.Net · https://teachers.net/lessons/3270.html